The HAMILTON-C1 neo ventilator combines invasive and noninvasive modes* with the options of nCPAP and high flow oxygen therapy in a single, compact device. Both the small footprint and the integrated highperformance turbine, which enables the HAMILTON-C1 neo to be operated independently of a compressed air supply, ensure maximum mobility. This makes it an ideal companion for your smallest patients in the intensive care unit, emergency ward, recovery or delivery room, as well as during intrahospital transport.
State-of-the-art invasive ventilation modes, Synchronized noninvasive ventilation, Demand-flow nCPAP modes, High flow oxygen therapy. Independent of compressed air supply, Optional SpO2 and CO2 measurement. Leak compensation in every mode.
More than 4 hours of battery operating time and less than 5 kg in weight.
The HAMILTON-C1 neo provides tidal volumes as low as 2 ml for effective, safe, and lung-protective ventilation even for the smallest patients.1 Both the proximal flow sensor, designed to minimize dead space, and the neonatal expiratory valve were developed specifically for neonates. The precise measurement of pressure, volume, and flow directly at the airway opening ensures the required sensitivity and a quick response time. Your most fragile patients should benefit from better synchronization and less work of breathing as a result.


The care of infants and in particular neonates is hugely challenging. Their unique physiological and developmental needs require specialised, precise treatment. Nobody is more aware of this than SLE, having focused solely on the design and manufacture of infant ventilators since the 1980s.
The SLE6000’s specialist lung-protective features include SLE’s own High Frequency Oscillation Ventilation (HFOV) using proprietary bidirectional jets, Pressure Support Ventilation (PSV), Volume Targeted Ventilation (VTV) and a choice of non-invasive ventilation modes (NIV) including High Flow Therapy.
The SLE6000 sees the introduction of the new Lunar™ interface,which incorporates a low-glare screen (in keeping with the increased emphasis on developmental care) whilst setting a new benchmark in usability.
The SLE6000 is a high-specification, compact infant ventilator that offers a range of conventional modes with additional options for non-invasive ventilation (NIV), high frequency oscillation ventilation (HFOV) and high flow oxygen therapy.
SpO2 and etCO2 monitoring options are supported with the addition of plug-in modules. OxyGenie (Auto O2) can also be integrated.


The HAMILTON-C6 represents a new generation of high-end ventilators. The combination of modularity, ease of use, mobility, and advanced features allows you to individualize your patient's ventilation therapy
The HAMILTON-C6 continuous the tradition of its predecessors and comes packed with Intelligent Ventilation technologies. Apart from the advanced ventilation modes ASV® and INTELLiVENT®-ASV, the HAMILTON-C6 offers tools for lung assessment and recruitment maneuvers, continuous cuff pressure management,transpulmonary pressure measurement, state-of-the-art ventilation monitoring and an integrated humidifier control.
State-of-the-art ventilation modes for adult,pediatric, and optional neonatal patients
Adaptive, lung-protective ventilation modes, ASV® and INTELLiVENT®-ASV, IntelliSync+ real-time patient synchronization, High-performance noninvasive ventilation, High flow oxygen therapy, P/V Tool Pro for lung assessment and recruitment, Transpulmonary pressure measurement, Integrated IntelliCuff® pressure controller, Integrated HAMILTON-H900 humidifier control.
Flexible device configuration, The HAMILTON-C6 adapts to your individual user environment. Mount it on a trolley, with the interaction panel on top or in front, or use the shelf-mounted version with the interaction panel on the side or mounted on the pendant system.
For intrahospital transport Thanks to the slender frame, an integrated O2 cylinder carrier, and the high-performance turbine, the HAMILTON-C6 can stay at your patient's side for intrahospital transports.
Ergonomic maneuverability With a compact footprint and high-quality trolley wheels the HAMILTON-C6 is designed for easy handling and maneuverability.
Download Hanilton C6 Configuration
Download Hamilton C6 IntelliSync


The HAMILTON-G5 is Hamilton Medical’s most modular high-end mechanical ventilator. A large set of standard features and options allows you to tailor the HAMILTON-G5 to your needs. The integrated cuff pressure controller IntelliCuff® continuously monitors and maintains a set cuff pressure in real-time. The Protective Ventilation Tool (P/V Tool Pro) provides a repeatable method to assess recruitability and find the best PEEP based on respiratory mechanics, as well as providing an easy and repeatable method for performing recruitment maneuvers. The HAMILTONG5 also supports transpulmonary pressure measurement.
In addition to many other features, the HAMILTON-G5 includes Hamilton Medical’s standardized Ventilation Cockpit user interface and the intelligent ventilation mode, Adaptive Support Ventilation (ASV®).
Provide patient-centered care with fewer resources
Unlike conventional modes, which require you to set many parameters, closed-loop ventilation with Adaptive Support Ventilation (ASV) requires attention to just one: minute ventilation. Studies show that ASV can be used to ventilate virtually all intubated patients – whether active or passive and regardless of the lung disease.

See all important information at a glance, Monitoring in mechanical ventilation means curves, loops, numbers and more numbers. But what do they tell us about the patient’s condition? The HAMILTON-G5 is the first ventilator to provide a Ventilation Cockpit that visualizes the patient’s respiratory mechanics and ventilatory support in an intuitive way.
Efficiency through innovation
The HAMILTON-G5 lets you optimize clinical resources and skills while reducing cost of ownership and management overhead, and most importantly, it can help you reduce the patient's time on the ventilator. The HAMILTON-G5’s intuitive interface simplifies ventilator setup and translates into easy training and less chance of operator error.
Fewer user interactions and less alarms with Adaptive Support Ventilation (ASV)
Integrated cuff pressure control to reduce VAP and tracheal injuries
A Ventilation Cockpit that is designed to improve safety through intuitive operation and monitoring
Proven closed-loop ventilation that automatically applies lung-protective strategies, reducing the risk of operator error and promoting early weaning
Safe ventilation for the smallest with responsive flow triggering and volume monitoring
Transpulmonary-pressure-measuremen with ballon catheter and feed.
Advanced ventilation modes including ASV and INTELLiVENT-ASV
Automated cuff pressure controller IntelliCuff
P/V Tool Pro for lung assessment and recruitment
Transpulmonary pressure measurement
High-flow oxygen therapy
Adult, pediatric, and neonatal ventilation
Trending Simultaneous display of up to 17 parameter trends, selected from all monitoring parameters, for 1, 3, 12, 24, or 96h
Hamilton SP02 and CO2 Brochure


The HAMILTON-C3 ventilator is a modular high-end ventilation solution for all patient groups.
Offering a number of unique features, the HAMILTON-C3 is one of the first ventilators featuring the “Ventilation Autopilot” INTELLiVENT®-ASV®. The HAMILTON-C3’s compact design and independence from compressed air allow maximum mobility throughout the hospital.
To meet the ever-growing demand for data transferability in the hospital environment, Hamilton Medical ventilators offer a serial RS-232 interface and several protocols for connection to patient monitoring systems, Electronic Health Records (EHR), Electronic Medical Record systems (EMR), and Patient Data Management Systems (PDMS).


The HAMILTON-C1 is designed to ventilate the adult, paediatric and Neonatal ICU patients.
The HAMILTON-C1 is unique in providing outstanding non-invasive performance in a full featured intensive care ventilator. Due to its very compact design, it offers maximum flexibility in various user environments, be it long term care, intensive care, emergency, or respiratory care. HAMILTON-C1 ventilator's compact, powerful design also increases the availability of appropriate modes of therapy for ventilated hospital patients. Small enough to fit into almost any ICU environment and competitively priced, they cover the full range of clinical requirements: invasive ventilation, automated ventilation with Adaptive Support Ventilation (ASV), and Non-Invasive Ventilation (NIV).
Changing breathing patterns or circuit leaks are a challenge in non-invasive ventilation. With the innovative IntelliTrig technology, the HAMILTON-C1 automatically responds to varying leaks and adapts sensitivity thresholds for optimal response to the patient’s breath.
ASV employs lung-protective strategies to minimize complications from AutoPEEP and resultant volutrauma and barotrauma. ASV also prevents apnea, tachypnea, excessive dead space ventilation and excessively large breaths.3 ASV guides the patient in a favorable breathing pattern, avoiding potentially detrimental patterns, from fully supported ventilation to extubation.
HAMILTON-C1 ventilators deliver a cost effective ICU ventilation solution that is appropriate for all patients – from children to adults. In the ICU, in the recovery room, and in long term care, HAMILTON-C1’s fast setup and easy management ensure the most appropriate treatment for every patient. HAMILTON-C1 systems combine reliability and high performance with advanced lung protective strategies and patient-adaptive modes. They are the ideal choice for ICU special care areas, cardiac surgery recovery rooms, stepdown or subacute care units, and long-term care centers.
The Hamilton Connect Module integrated in the ventilator provides the HAMILTON-C1/T1 with the capability of secure wireless communication with patient data management systems, monitoring systems, and the Hamilton Connect App.
Hamilton Connect App connects your mobile device to your Hamilton Medical ventilator and allows you to access selected ventilation data.
Besides its unique features, the HAMILTON-C1 includes everything you expect from a high-performance ICU ventilator:
The software update v3.0.x brings many new features and improvements:


This state-of-the-art ventilator provides you with the world’s first fully closed-loop ventilation solution, INTELLiVENT®-ASV, that fully automatically applies lung protective strategies, reduces the risk of operator errors and encourages early weaning. The HAMILTON-S1 is a universal ventilator capable of invasive and non-invasive therapy for the entire patient range of neonates to adults, providing nasal CPAP, including a robust leakage compensation patient trigger through Hamilton IntelliTrig.
INTELLiVENT®-ASV, the unique application on the HAMILTON-S1, guides you when making complex decisions, even if there is no respiratory expert available. What makes INTELLiVENT®-ASV revolutionary is that it does more than just make recommendations; it also performs ventilation adjustments automatically. Unlike conventional modes, which require you to set many parameters manually, INTELLiVENT®-ASV relieves you from routine adjustments by following patient’s demand at all times.
HAMILTON-S1 with INTELLiVENT®-ASV can help reduce the burden of routine tasks in mechanical ventilation and reduce false positive alarms, giving you more time and providing increased safety for your patients. While conventional ventilators deliver only user defined breaths to the patient, INTELLiVENT®-ASV automatically adapts ventilation and oxygenation on a continuous basis, according to the changing patient status.
INTELLiVENT®-ASV provides 24/7 optimized ventilation to the patient, regardless of how many ventilated patients or respiratory specialists your hospital may have. INTELLiVENT®-ASV ensures optimized protocolized care at all times.
The HAMILTON-S1 with INTELLiVENT®-ASV includes everything you expect from a leading ventilation solution:
With INTELLiVENT®-ASV‘s automation capabilities, ventilation and oxygenation of the patient are controlled by automatically setting the Minute ventilation, PEEP and FiO2. A set of complex algorithms work together to enable INTELLiVENT®-ASV to completely close the loop in mechanical ventilation, covering all phases of ventilation from intubation through extubation.
INTELLiVENT®-ASV relies on noninvasive sensors for SpO2 using pulse oximetry and end-tidal CO2 (etCO2) for CO2. INTELLiVENT®-ASV uses proprietary algorithms to analyze signals from multiple pulse oximetry sensors as well as the main stream capnometer to produce filtered artifact-free SpO2 and EtCO2 values, respectively. These values are robust enough to adjust oxygen and PEEP, and to also give you an EtCO2 value close to PaCO2.